Expensive radiators? Here’s how to read heat cost allocators to avoid surprises

ADNKRONOS

November 13, 2026

Rome, Nov 12. (Adnkronos/Labitalia) – Mandatory since 2017 in condominiums with central heating, heat cost allocators determine how much each person pays for heating. But how do you read them? Agnese Giardini from Immobiliare.it sheds light on one of the expenses affecting Italian families. The heat cost allocator, more correctly called a heating cost distributor, is the small device applied to the surface of radiators in buildings with central heating systems. It does not measure heat in kilowatt-hours like a real meter would, but instead records how much heat each radiator gives off compared to others in the building, so that the cost of condominium heating can be divided based on actual use and not just property shares.

Since June 30, 2017, all condominiums with central heating must have a system that measures the consumption of each apartment. Installation can only be avoided if a technician certifies that it is not feasible or not economically convenient. 2027 brings a novelty, because by January 1st, all heat cost allocators must be remotely readable, without anyone having to enter homes to check them. The law not only requires measuring how much heat each apartment consumes, but also giving residents the ability to regulate it. For this reason, the heat cost allocator is installed together with a thermoregulation system, i.e., devices that allow choosing the temperature of each room. With the old system based on property shares, the expense was divided proportionally to the size of the apartment, regardless of actual use; Now, instead, those who keep radiators off in an unused room or lower the temperature when leaving home pay less, while those who heat more bear a larger share.

But how do probes, microchips, and displays work? The electronic allocator is fixed to the radiator, usually halfway across its width and about three-quarters of its height, where the surface temperature is most representative. Inside, there are one or two probes: the first, in contact with the metal, detects the radiator’s temperature; the second, present in dual-sensor models, measures the ambient temperature. A microchip processes the difference between the two values over time and converts it into consumption units according to the criteria of the European standard UNI EN 834. Counting only starts when the radiator exceeds a certain temperature, and the ambient probe helps to avoid mistaking heat produced by other sources for consumption. The data appears on a small display and, in newer models, is transmitted via radio. Direct metering is used in horizontal distribution systems, where hot water enters apartments from a single point. A single heat meter per unit is sufficient, measuring flow rate and the temperature difference between supply and return, and returning a value in kilowatt-hours. In older buildings, with vertical riser systems that cross floors, each radiator is connected to a different pipe, and in this case, indirect metering is used, with an allocator on each radiator. The result is not an absolute measure of energy but a proportional share, which translates into expense only after the overall calculation.

How is the heat cost allocator installed? The first step is to appoint a technician who verifies feasibility and draws up the project, then the assembly chooses the company and approves the work. Law 10/1991, as amended by the 2012 condominium reform, stipulates that these decisions are made by a majority of those present representing at least half the value of the building, without requiring unanimity. Once the resolution is approved, the individual condominium owner cannot deny technicians access to the apartment. Installation is quick, does not require masonry work, and almost always does not require disassembling the radiators. The allocator alone does not save money. Savings come with thermostatic valves, installed together with the meters instead of normal taps. The graduated head, with a scale usually ranging from 1 to 5, progressively closes the flow of hot water when the room reaches the set temperature, thus avoiding overheating the rooms and utilizing free contributions, such as sunlight entering through windows or heat from stoves.

The numbers on the display are consumption units, dimensionless values that only make sense when compared to the total of the building. By pressing the device button, or automatically in some models, different screens appear in rotation. The main ones show the consumption for the current season, the value stored at the end of the previous season, the corresponding date, and a control code. If the allocator shows raw units, multiplied by the radiator coefficients only during calculation, the numbers of two different radiators cannot be compared by eye. To get oriented, it is useful to note the figures at the beginning of the season and check them periodically. Furthermore, with remotely readable devices, users must receive monthly information on their consumption during the heating season.

The total expense is divided into two parts: the share of voluntary consumption depends on the readings of the allocators and is what each person controls with their own choices; the share of involuntary consumption, on the other hand, covers network distribution losses and is divided by property shares, square meters, or cubic meters. The reference for calculation is the technical standard UNI 10200. However, the law allows dividing the expense only by property shares in the first season after installation. When real estate units have very different thermal needs, with discrepancies exceeding 50% such as between an exposed attic and a central apartment, at least 50% of the expense can be attributed to voluntary consumption, and the rest can be divided using other criteria. The cost depends on the number of radiators, the type of device, and the presence or absence of thermostatic valves. For the allocator alone, the cost is generally a few tens of euros per radiator, up to about 100 euros for radio-enabled models. To this figure are added valves, heads, project, and adaptation of the heating plant. Many condominiums choose rental, which includes maintenance and readings with an annual fee. Those who do not comply risk an administrative sanction from 500 to 2,500 euros for each real estate unit, as provided by Article 16 of Legislative Decree 102/2014.

Jiji Press